Mantis Bugtracker
  

Viewing Issue Simple Details Jump to Notes ] View Advanced ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0001933 [Resin] major always 08-10-07 02:23 08-13-07 09:02
Reporter forrest View Status public  
Assigned To ferg
Priority normal Resolution fixed  
Status closed   Product Version 3.0.19
Summary 0001933: When archiving the access log, Resin stops response
Description During resin archiving the access log file around 00:00, Resin stops response to any visit. Because our website is very busy, the archiving process may cost 5 minutes. So, our website will be no responding for 5 minutes.
Additional Information We run resin on Windows 2003.
Attached Files

- Relationships

- Notes
(0002189)
ferg
08-13-07 09:02

This is fixed in the 3.1 tree.

In 3.0, it may be possible to avoid the archive time by using path-format in the access-log. Since path-format will create the access log in-place, there's no need to wait for the rollover.

Also, the rollover-period or rollover-size can be reduced to reduce the time taken by the rollover.
 

- Issue History
Date Modified Username Field Change
08-10-07 02:23 forrest New Issue
08-13-07 09:02 ferg Note Added: 0002189
08-13-07 09:02 ferg Assigned To  => ferg
08-13-07 09:02 ferg Status new => closed
08-13-07 09:02 ferg Resolution open => fixed
08-13-07 09:02 ferg Fixed in Version  => 3.1.2


Mantis 1.0.0rc3[^]
Copyright © 2000 - 2005 Mantis Group
29 total queries executed.