0001933 [Resin] major always 08-10-07 02:23 08-13-07 09:02
Reporter forrest View Status public  
Assigned To ferg
Priority normal Resolution fixed Platform
Status closed   OS
Projection none   OS Version
ETA none Fixed in Version 3.1.2 Product Version 3.0.19
  Product Build
Summary 0001933: When archiving the access log, Resin stops response
Description During resin archiving the access log file around 00:00, Resin stops response to any visit. Because our website is very busy, the archiving process may cost 5 minutes. So, our website will be no responding for 5 minutes.
Steps To Reproduce
Additional Information We run resin on Windows 2003.
Attached Files

- Relationships

- Notes
(0002189)
ferg
08-13-07 09:02

This is fixed in the 3.1 tree.

In 3.0, it may be possible to avoid the archive time by using path-format in the access-log. Since path-format will create the access log in-place, there's no need to wait for the rollover.