Mantis Bugtracker
  

Viewing Issue Simple Details Jump to Notes ] View Advanced ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0002819 [Hessian] minor always 08-04-08 09:08 08-07-08 10:56
Reporter ferg View Status public  
Assigned To ferg
Priority normal Resolution fixed  
Status closed   Product Version
Summary 0002819: stream length needs to be unsigned
Description (rep by Niclas Olofsson)

It says in the spec that the string _length_ is encoding in 16 bits. From
the Java encoder I noticed that it is a signed 16 bit. Is that how I
should interpret the spec too? Leaves a lot of bits unused...

Additional Information
Attached Files

- Relationships

- Notes
(0003297)
ferg
08-07-08 10:56

cleaned up specification to clarify that the length is 16-bits unsigned.
 

- Issue History
Date Modified Username Field Change
08-04-08 09:08 ferg New Issue
08-07-08 10:56 ferg Note Added: 0003297
08-07-08 10:56 ferg Assigned To  => ferg
08-07-08 10:56 ferg Status new => closed
08-07-08 10:56 ferg Resolution open => fixed
08-07-08 10:56 ferg Fixed in Version  => 3.2.1


Mantis 1.0.0rc3[^]
Copyright © 2000 - 2005 Mantis Group
28 total queries executed.
25 unique queries executed.