Summary 0004906: IIS Plugin Logger does not check log level correctly.
Description In the source for the IIS-ResinHandler, the Logger.cs has a method IsLoggable:

internal bool IsLoggable(EventLogEntryType entryType) {
    return entryType < _logLevel;
}

The check should use the <= operator instead of the <, since if the log level was set to Information, IsLoggable(Information) should return **true**.

Additional Information
Attached Files

- Relationships

There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
12-27-11 10:57 TheScrumMeister New Issue
12-27-11 15:38 TheScrumMeister Issue Monitored: TheScrumMeister
03-05-12 08:57 alex Status new => assigned
03-05-12 08:57 alex Assigned To  => alex
03-05-12 09:25 alex Status assigned => closed
03-05-12 09:25 alex Resolution open => fixed
03-05-12 09:25 alex Fixed in Version  => 4.0.27